Part Number Hot Search : 
A1328 MTD907 MC100EP 74LVC1G P4C12 1212E 81622 MAX3377
Product Description
Full Text Search
 

To Download PFE600-12-054NA Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  bcd.00037 rev. ab, 19jan2011 page 1 / 8 www.power-one.com PFE600-12-054NA short form data sheet 600 watts, 12 vdc output applications ? high performance servers, routers, and switches . features ? bestinclass, 80 plus certified platinum effic iency ? wide input voltage range: 90264 vac ? ac input with power factor correction ? alwayson 16.5w programmable standby output (3.3/ 5 v) ? hotplug capable ? parallel operation with active digital current sh aring ? full digital controls for improved performance ? high density design: 14.0 w/in 3 ? small form factor: 54.5 x 40.0 x 321.5 mm ? i 2 c communication interface for control, programming and monitoring with psmi and pmbus? protocol ? overtemperature, output overvoltage and overcurre nt protection ? 256 bytes of eeprom for user information ? 2 status leds: ac ok and dc ok with fault signali ng description the pfe60012054na is a 600 watt, ac to dc powerf actorcorrected (pfc) power supply that converts st andard ac mains power into a main output of 12 vdc for powering int ermediate bus architectures (iba) in high performan ce and reliability servers, routers, and network switches. the pfe600 12054na meets international safety standards and d isplays the cemark for the european low voltage directive (lvd). 88 89 90 91 92 93 94 95 0 100 200 300 400 500 600 po [w] power factor vi = 230vac; fan external vi = 230vac; fan internal platinum 0.8 0.82 0.84 0.86 0.88 0.9 0.92 0.94 0.96 0.98 1 0 100 200 300 400 500 600 po [w] power factor 230vac 115vac ordering information pfe 6 00 - 12 - 054 n a product family pfe frontends power level 600w dash v1 output 12v dash width 54mm airflow n: normal r: reversed input a: ac d: dc
bcd.00037 rev. ab, 19jan2011 page 2 / 8 www.power-one.com PFE600-12-054NA short form data sheet 600 watts, 12 vdc output 1 environmental and mechanical parameter conditions / description min nom max unit t a ambient temperature v i min to v i max , i 1 nom , i sb nom 0 +45 c t aext extended temp range derated output (600 to 450w out put power) +45 +65 c t s storage temperature nonoperational 20 +70 c n a audible noise v i nom , 50% i o nom , t a = 25c 42 dba dimensions width 54.5 mm height 40.0 mm depth 321.5 mm m weight 950 g 2 input specifications general condition: t a = 0 45 c unless otherwise noted. parameter conditions / description min nom max unit v i nom nominal input voltage 100 230 240 vac v i input voltage ranges normal operating ( v i min to v i max ) 90 264 vac i i max max input current 8.5 a rms i i p inrush current limitation v i min to v i max , 90, t ntc = 25c 40 a p f i input frequency 47 50/60 64 hz pf power factor v i nom , 50hz, > 0.2 i 1 nom 0.9 w/va v i on turnon input voltage 1) ramping up 80 87 vac v i off turnoff input voltage 1) ramping down 75 85 vac efficiency without fan v i nom , 0.1 i x nom , v x nom , t a = 25 c 85.4 % v i nom , 0.2 i x nom , v x nom , t a = 25 c 92.8 v i nom , 0.5 i x nom , v x nom , t a = 25 c 94.5 v i nom , i x nom , v x nom , t a = 25 c 94.0 t hold holdup time after last ac zero point, v 1 > 10.8 v, v sb within regulation, v i = 230 vac, p x nom 20 ms 1) the frontend is provided with a minimum hysteresi s of 3 v during turnon and turnoff within the ran ges.
bcd.00037 rev. ab, 19jan2011 page 3 / 8 www.power-one.com PFE600-12-054NA short form data sheet 600 watts, 12 vdc output 3 output specifications general condition: t a = 0 +45 c unless otherwise noted. parameter conditions / description min nom max unit main output v 1 v 1 nom nominal output voltage 0.5 i 1 nom , t amb = 25 c 12.0 vdc v 1 set output setpoint accuracy 0.5 +0.5 % v 1 nom d v 1 tot total regulation v i min to v i max , 0 to 100% i 1 nom , t a min to t a max 1 +1 % v 1 nom p 1 nom nominal output power v 1 = 12 vdc 600 w i 1 nom nominal output current v 1 = 12 vdc 50.0 adc v 1 pp output ripple voltage v 1 nom , i 1 nom , 20 mhz bw, 2pcs 47f/16v/x5r/1210 at v 1 150 mvpp d v 1 load load regulation v i = v i nom , 0 100 % i 1 nom 33 mv d v 1 line line regulation v i =v i min v i max 0 mv i 1 max current limitation t a < 45 c 52.5 55 adc d i share current sharing deviation from i 1 tot / n, i 1 > 10a 3 +3 a d v dyn dynamic load regulation i 1 = 50% i 1 nom , i 1 = 5 100% i 1 nom , d i 1 /d t = 1 a/s, recovery within 1% of v 1 nom 0.6 0.6 v t rec recovery time 1 ms t ac v1 startup time from ac v 1 = 10.8 vdc 2 sec t v1 rise rise time v 1 = 1090% v 1 nom 1 10 ms c load capacitive loading v1 t a = 25 c 30000 f standby output v sb v sb nom nominal output voltage 0.5 i sb nom , t amb = 25 c vsb_sel = 1 3.3 vdc vsb_sel = 0 5.0 vdc v sb set output setpoint accuracy vsb_sel = 0 / 1 0.5 +0.5 % v sbnom dv sb tot total regulation v i min to v i max , 0 to 100% i sb nom , t a min to t a max 1 +1 % v sbnom p sb nom nominal output power vsb_sel = 0 / 1 16.5 w i sb nom nominal output current v sb = 3.3 vdc 5 adc v sb = 5.0 vdc 3.3 adc v sb pp output ripple voltage v sb nom , i sb nom , 20 mhz bw, 10f/16v/x7r/1206 at v sb 40 mvpp d v sb droop 0 100 % i sb nom vsb_sel = 1 67 mv vsb_sel = 0 44 mv i sb max current limitation vsb_sel = 1 5.25 6 adc vsb_sel = 0 3.45 4.3 adc d v sbdyn dynamic load regulation i sb = 50% i sb nom , i sb = 5 100% i sb nom , d i o /d t = 0.5 a/s, recovery within 1% of v 1 nom 3 3 % v sbnom t rec recovery time 250 s t ac vsb startup time from ac v sb = 90% v sb nom 2 sec t vsb rise rise time v sb = 1090% v sb nom 4 20 ms
bcd.00037 rev. ab, 19jan2011 page 4 / 8 www.power-one.com PFE600-12-054NA short form data sheet 600 watts, 12 vdc output parameter conditions / description min nom max unit standby output v sb (cont.) c load capacitive loading t amb = 25 c 10000 f 4 signaling and control 4.1 front leds table 1: led status operating condition led signaling ac led ac line within range solid green ac line uv condition off dc led 1) pson high blinking yellow (1:1) hotstandby mode blinking yellow/green (1:2) v 1 or v sb out of regulation solid yellow over temperature shutdown output over voltage shutdown ( v 1 or v sb ) output over current shutdown ( v 1 or v sb ) fan error (>15%) over temperature warning blinking yellow/green (2:1 ) minor fan regulation error (>5%, <15%) blinking yel low/green (1:1) 1) the order of the criteria in the table corresponds to the testing precedence in the controller. the frontend has 2 front leds showing the status o f the supply. led number one is green and indicates ac po wer is on or off, while led number two is bicolored: g reen and yellow, and indicates dc power presence or fault situations. for the position of the leds see figure 5. 4.2 graphical user interface powerone provides with its powerone i 2 c utility a windows? xp/vista/win7 compatible graphical user interface allowing the programming and monitoring o f the pfe60012054na frontend. the utility can be downloaded on www.powerone.com and supports both the psmi and pmbus? protocols. the gui allows automatic discovery of the units connected to the communication bus and will show th em in the navigation tree. in the monitoring view the pow er supply can be controlled and monitored. if the gui is used in conjunction with the pfe6001 2 054na evaluation kit it is also possible to control the pson pin(s) of the power supply. further there is a button to disable the internal f an for approximately 10 seconds. this allows the user to t ake input power measurements without fan consumptions t o check efficiency compliance to the climate saver computing platinum specification. figure 1: i 2 c bus to dsp and eeprom the monitoring screen also allows to enable the hot standby mode on the power supply. the mode status i s monitored and by changing the load current it can b e monitored when the power supply is being disabled f or further energy savings. this obviously requires 2 p ower supplies being operated as a redundant system (like the evaluation kit). note: the user of the gui needs to ensure that only one of the power supplies have the hotstandby mode enable d.
bcd.00037 rev. ab, 19jan2011 page 5 / 8 www.power-one.com PFE600-12-054NA short form data sheet 600 watts, 12 vdc output 5 electromagnetic compatibility 5.1 immunity note: most of the immunity requirements are derived from en 55024:1998/a2:2003. test standard / description criteria esd contact discharge iec / en 6100042, 8 kv, 25+25 discharges per tes t point (metallic case, leds, connector body) b esd air discharge iec / en 6100042, 15 kv, 25+25 discharges per te st point (non metallic user accessible surfaces) b radiated electromagnetic field iec / en 6100043, 10 v/m, 1 khz/80% amplitude mod ulation, 1 s pulse modulation, 10 khz2 ghz a burst iec / en 6100044, level 3 ac port 2 kv, 1 minute dc port 1 kv, 1 minute b surge iec / en 6100045 line to earth: level 3, 2 kv l ine to line: level 2, 1 kv b rf conducted immunity iec/en 61000 4 6, level 3, 10 vrms, cw, 0.1 80 mhz a voltage dips and interruptions iec/en 61000411 1: vi 230v, 100% load, phase 0, dip 100%, duratio n 10 ms 2: vi 230v, 100% load, phase 0, dip 100%, duratio n 20 ms 3: vi 230v, 100% load, phase 0, dip 100%, duratio n >20ms a a b 5.2 emission test standard / description criteria conducted emission en55022 / cispr 22: 0.15 30 mhz, qp and avg, s ingle unit class a 6 db margin en55022 / cispr 22: 0.15 30 mhz, qp and avg, 2 units in rack system class a 6 db margin radiated emission en55022 / cispr 22: 30 mhz 1 ghz, qp, single unit class a 6 db margin en55022 / cispr 22: 30 mhz 1 ghz, qp, 2 units in rack system class a 6 db margin harmonic emissions iec61000 3 2, vin = 100 vac/ 60 hz, 100% load class a iec61000 3 2, vin = 120 vac/ 60 hz, 100% load class a iec61000 3 2, vin = 200 vac/ 60 hz, 100% load class a iec61000 3 2, vin = 230 vac/ 50 hz, 100% load class a iec61000 3 2, vin = 240 vac/ 50 hz, 100% load class a acoustical noise sound power statistical declaration (iso 9296, iso 7779, is9295) @ 50% load 42 dba
bcd.00037 rev. ab, 19jan2011 page 6 / 8 www.power-one.com PFE600-12-054NA short form data sheet 600 watts, 12 vdc output 6 mechanical 6.1 dimensions 1 98 321.5 0.4 25 2.4 34.6 14 0.6 13.4 figure 2: side view 1 9.5 80 40 12.25 4.4 8 figure 3: top view 0.6 8.75 figure 4: side view 2 main pcb 8.75 0.6 2.15 40 12.25 8 36 54.5 10.5 22 1.6 4 44.04 9.44 5.23 0.6 14 figure 5: front view ac led dc led note: a 3d step file of the power supply casing is available on request. air flow direction note: unlatching the supply is performed by pulling the green trigger in the handle.
bcd.00037 rev. ab, 19jan2011 page 7 / 8 www.power-one.com PFE600-12-054NA short form data sheet 600 watts, 12 vdc output 6.2 connections unit: tyco electronics p/n 219267363 note: colu mn 5 is lagging (short pins) counter part: tyco electronics p/n 219267335 pin name description output 6, 7, 8, 9, 10 v 1 + 12 vdc main output 1, 2, 3, 4, 5 pgnd power ground (return) control pins a1 vsb standby positive output (+3.3/5 v) b1 vsb standby positive output (+3.3/5 v) c1 vsb standby pos itive output (+3.3/5 v) d1 vsb standby positive output (+3.3/5 v) e1 vsb standby positive output (+3.3/5 v) a2 sgnd signal ground (return) b2 sgnd signal ground (return) c2 hotstandbyen hot standby enable signal d2 vsb_sense_r standby output negative sense e2 vsb_sense standby output positive sense a3 aps i 2 c address and protocol selection (select by a pull down resistor) b3 nc reserved c3 sda i 2 c data signal line d3 v1_sense_r main output negative sense e3 v1_sense main output positive sense a4 scl i 2 c clock signal line b4 ps on power supply on input (connect to a2/b2 to turn uni t on) c4 smb_alert smb alert signal output d4 nc reserved e4 ac ok ac input ok signal a5 pskill power supply kill (lagging pin) b5 ishare current share bus (laggin g pin) c5 pw ok power ok signal output (lagging pin) d5 vsb_sel standby voltage selection (lagging pin) e5 present_l power supply present (lagging pin)
bcd.00037 rev. ab, 19jan2011 page 8 / 8 www.power-one.com PFE600-12-054NA short form data sheet 600 watts, 12 vdc output 7 accessories item description ordering part number source power-one i 2 c utility windows xp/vista/7 compatible gui to program, control and monitor pfe frontends (and other i 2 c units) n/a www.powerone.com usb to i 2 c converter master i 2 c device to program, control and monitor i 2 c units in conjunction with the power-one i 2 c utility zm00056 powerone dual connector board connector board to operate 2 pfe units in parallel. includes an onboard usb to i 2 c converter (use power-one i 2 c utility as desktop software). snpopboard01 powerone copyright ? 2010 powerone inc. all rights reserved . words and logos that are identified as trademarks and/or service marks are, unless noted otherwise, the trademarks and service marks of powerone inc. in the u.s. and other countries. all other product or service name s are the property of their respective holders. pow erone products are protected under numerous u.s. and foreign paten ts and pending applications, maskwork rights, and c opyrights. powerone reserves the right to make cha nges to any products and services at any time without notice. p owerone assumes no responsibility or liability ari sing out of the application or use of any informati on, product, or service described herein except as expressly agreed to in w riting by powerone inc. 1. nuclear and medical applications powerone pr oducts are not designed, intended for use in, or au thorized for use as critical components in life sup port systems, equipment used in hazardous environments, or nuclear control systems without the express writ ten consent of the respective divisional president of powerone, inc. 2. technical revisions the appearance of products , including safety agency certifications pictured o n labels, may change depending on the date manufact ured. specifications are subject to change without notice .


▲Up To Search▲   

 
Price & Availability of PFE600-12-054NA

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X